Compressor Problems
The compressor is the pump in a heat pump. When it stops, there is no heating or cooling from the outdoor unit at all. Not every no-start is a dead compressor, though. A failed capacitor or contactor can look the same. Before you accept a heat pump compressor replacement, call and we connect you with an independent local contractor in Parker who can test it properly.
Call (303) 647‑3227 →Related Pages

Why They Fail
Compressors are built to last many years, and most failures trace back to something else that went wrong first. These four causes come up most when a contractor looks at a failed or struggling compressor, and several appear on our heat pump problems page too.
✓
Starting component failure. A weak run capacitor or pitted contactor makes the compressor struggle to start, so it overheats and trips its internal overload.
✓
Running low on refrigerant. Refrigerant also cools the compressor motor. A long term leak lets it run hot until the windings break down.
✓
Liquid refrigerant flooding back. A failed expansion valve (TXV) or a defrost fault can send liquid into the compressor, which is built to pump vapor. That damages valves inside.
✓
Electrical winding failure. Age, heat and voltage spikes break down the motor windings. A grounded compressor often trips the breaker the moment it tries to start.
Repair or Replace
A compressor in Parker works harder than one in a mild climate. Long heating runs through cold snaps and summer runs under strong sun add up. When one fails, the choice between replacing the compressor and replacing the outdoor unit or the whole system depends on the unit's age, the refrigerant it uses, part availability and the condition of the coils.
Do not keep resetting a breaker that trips each time the compressor tries to start. Switch the system off at the thermostat and breaker and stay safe. Do not let anyone talk you into a new compressor without testing the capacitor and contactor first. Those parts are far smaller jobs and fail more often.
A compressor problem is urgent when you lose heat in winter or hear loud humming, clanking or a burning smell from the outdoor unit. Emergency Heat can hold the house in the meantime. Our page on repair versus replacement covers the bigger decision.
Call (303) 647‑3227 →
Before You Call
01
If the outdoor unit breaker has tripped, reset it one time. If it trips again, leave it off and call.
02
With the system calling for heat or cooling, listen near the outdoor unit. A hum with no fan, or a click and silence, helps the contractor.
03
In winter, set the thermostat to Emergency Heat so the house stays warm and the outdoor unit stops trying to start.